User Tools

Site Tools


ingenico_i6550_-_the_missing_article

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Last revisionBoth sides next revision
ingenico_i6550_-_the_missing_article [2014/06/26 15:57 (10 years ago)] fgabianaingenico_i6550_-_the_missing_article [2014/11/05 09:38 (10 years ago)] craig
Line 70: Line 70:
 Once you've done this, you should be able to go to a command prompt on the Remote Desktop and type CHANGE PORT /QUERY to see the mapped COM Ports being forwarded, once you've done this you know that the Pin Pad will load forms. Once you've done this, you should be able to go to a command prompt on the Remote Desktop and type CHANGE PORT /QUERY to see the mapped COM Ports being forwarded, once you've done this you know that the Pin Pad will load forms.
  
-Next you're going to want to make sure the Pin Pad is configured properly for Serial. Hit [1] [CANCEL] & [ENTER] at the same time on the Pin Pad. Then hold down [1] [3] together straight away until the menu loads up. Then go to Supervisor Menu - Password 2634. Once you're in there go to System Parameters -> Setup Port. Go to PORT 1 & PORT 3 and make sure they're set to RS232 for Serial. On PORT 3 be sure to set the right value in the LOCAL IP PORT option i.e. Pin Pad 1 we might want as Port 8001, and Pin Pad 2 we might want 8002 etc. +Next you're going to want to make sure the Pin Pad is configured properly for Serial. Hit [1] [CANCEL] & [ENTER] at the same time on the Pin Pad. Then hold down [1] [3] together straight away until the menu loads up. Then go to Supervisor Menu - Password xxxx. Once you're in there go to System Parameters -> Setup Port. Go to PORT 1 & PORT 3 and make sure they're set to RS232 for Serial. On PORT 3 be sure to set the right value in the LOCAL IP PORT option i.e. Pin Pad 1 we might want as Port 8001, and Pin Pad 2 we might want 8002 etc. 
  
 The Cancel button will take the customer back a menu, it's also advisable to use fingers instead of the pen as the pen has a habit of pushing things you don't want. Using your finger on the bottom and top right of the screen should scroll up and down the menu also. Next you want to set the HOST PORT to PORT 1. Now hot cancel until you come out of all the menus and the Pin Pad reboots. Once it's rebooted and intialised it should say HostPort: COM1,RS232:8001 or something similar. The Cancel button will take the customer back a menu, it's also advisable to use fingers instead of the pen as the pen has a habit of pushing things you don't want. Using your finger on the bottom and top right of the screen should scroll up and down the menu also. Next you want to set the HOST PORT to PORT 1. Now hot cancel until you come out of all the menus and the Pin Pad reboots. Once it's rebooted and intialised it should say HostPort: COM1,RS232:8001 or something similar.
ingenico_i6550_-_the_missing_article.txt · Last modified: 2022/02/24 11:05 (2 years ago) by asegert_windwardsoftware.com